60KW 380V Hybrid Deye HP3 HV Inverter
Product details
· Compatible with diesel generator
· Smart battery charging/discharging with optimized algorithms
· Allows parallel connection up to 10 units (in on-grid and backup mode)
· Load and priority management via software
· Supports unbalanced loads 100% between phases
· Compatible with EMS/remote monitoring systems
· Remote shutdown and emergency function
· Integration with external BMS solutions
2.Protections and Certifications
· Protection against overvoltage, undervoltage, overcurrent, short circuit, overtemperature
· Galvanic isolation for safety
· Anti-islanding (protection against unwanted isolated operation)
· Certifications CEI, EN, IEC, VDE-AR-N 4105, G99, G83, etc.
· Differential and reverse polarity protection
3.Physical Design
· Approximate size: 606x927x314mm
· Active cooling system (integrated fans)
· Wall installation or installation on reinforced metal structures
4.Key Advantages
· All-in-one solution: solar inverter + battery inverter
· High efficiency and reliability
· Scalable for large commercial or industrial installations
· Complies with European grid connection regulations
· Ideal for self-consumption, storage, load balancing and backup
5.Typical Applications
· Industrial ships
· Shopping centers or logistics warehouses
· Agricultural facilities with high energy demand
· Microgrids or energy communities
· Systems with battery priority and self-consumption
6.General specifications
Feature |
Details |
Nominal output power (AC) |
60 kW / 70 kW / 75 kW / 80 kW (depending on model) |
Photovoltaic input (DC) |
Up to 120 kW / 140 kW / 150 kW / 160 kW |
MPPT |
6 independent MPPT trackers |
PV input voltage |
MPPT range: 200 – 1000 V; max. 1100V |
Battery input |
Compatible with lithium batteries, voltage: 160 – 1000 V |
Charge/discharge current |
Maximum 160 A (80 A + 80 A dual channels) |
Unlimited |
Max. 97.6%; MPPT > 99% |
AC output voltage |
3 phases (3L + N + PE), 380/400 V nominal |
Frequency |
50/60 Hz, network synchronization |
MPPT Efficiency |
>99% |
Weight and measurements |
Aprox. 98–109 kg 95*63*35 |
Degree of protection |
IP65 (outdoor use) |
· Lithium BMS Brands Compatibility List
· 100% unbalanced output, each phase Maximum output up to 50% of rated power
· DC couple and AC couple to upgrade existing solar system
· Maximum 10 pieces in parallel for on-grid and off-grid operation Supports multiple batteries in parallel
· Maximum charge/discharge current of 37A
· High voltage battery, higher efficiency.
· 6 time periods for battery charging/discharging
· Support diesel generator energy storage
· 6-MPPT
· Network Injection
· Zero injection
· Works with batteries
· Works without batteries
· P65 (Allows outdoor installation)
· Telecommunications with all brands of Lithium batteries
· 10 years warranty
· Entrance with solar panel
· Works On grid and Off grid at the same time
· Works in parallel between inverters
· Applications App (distance control)
· Official Telecommunications with Lithium Batteries: Pylontech, Dyness HIGH VOLTAGE 160-700VDC ETC….
· Wi-Fi
· 160-700VDC high voltage battery, transformer isolation design
· 6 time periods to charge/discharge the battery
· Max. 50A+50A charge/discharge current
· DC pair and AC pair to retrofit existing solar system
· Support diesel generator energy storage
· Unique smart charging app and grid peak reduction function
8.The Product Includes· Converter
· Hanging panel
· Installation screws M4*20 stainless steel
· AC connector
· MC4 Connector
· M6*80 expansion bolt 4
· Current sensor for zero flow
· User Manual
· stamp panel
Protecciones
· Photovoltaic input lightning protection:
· Integrated
· Anti-island protection
· Integrated
· Photovoltaic string input reverse polarity protection
· Integrated
· Insulation resistance detection
· Integrated
· Residual current monitoring unit
· Integrated
· Output overcurrent protection
· Integrated
· Output short circuit protection
· Integrated
· Output overvoltage protection
· Integrated
· surge protection
· DC Type II / AC Type II
9.Power Priority ModesSelf-consumption priority (default)
· Order of use:
Solar energy → Loads → Battery → Grid
· Ideal for maximize savings on your electricity bill.
Battery charging priority
· Order of use:
Solar energy → Battery → Loads → Grid
· It is used when the objective is charge the battery as quickly as possible, for example, for nighttime backup or in regions with frequent power outages.
Network priority (injection)
· Order of use:
Solar Energy → Grid → Loads / Battery
· Used when searching export energy to the grid at a favorable rate (net metering, compensation, etc.).
Backup mode (UPS)
· Fast switching during network outages (<10 ms)
· Prioritizes supply to critical loads from batteries and/or solar panels.
· Compatible with diesel generator in parallel
️ How do I set it up?
How do I set it up?
· The inverter LCD display, or through the monitoring platform (Solarman Smart or WebUIs).
· You access the “Work Mode” menu and you can choose between:
· Self-use (self-consumption)
· Feed-in Priority (injection/network)
· Battery First
· Manual (custom mode)
️Recommendation
· In most cases, the Self-Use mode (self-consumption) It is the most recommended, since:
· Reduces network consumption
· Take advantage of solar energy
· Maintains battery with moderate charge
· But if the client needs support o attractive injection rates, can be easily changed.
Packaging